<a id="ch-04"></a>

## Chapter 4 — Data models

### Learning outcomes

You will (1) design a simple asset table with keys and attributes; (2) choose identifiers that survive device replacement; (3) represent relationships such as "gateway serves loggers"; and (4) keep sensitive attributes out of general tables.

### 4.1 Tables, keys and attributes

An asset table holds one row per asset. The key must be unique and stable. IP addresses are poor keys because they change when a device is re-addressed; serial numbers change when a device is replaced. NCS uses an asset tag painted on the equipment (for example "MP-1/PLC-R1"), which stays with the function.

Priya's schema keys every table on that tag, which is how the asset, logger and flow tables join cleanly even after PLC-R2's documented firmware turned out to be wrong.

### 4.2 Relationships

Forty loggers report through GW-LOG. Storing "gateway" as an attribute of each logger row creates a one-to-many relationship that lets a query answer "which loggers go dark if GW-LOG fails?" in one line. Similarly, a flow table with source and destination keys links assets into the communication picture used in Chapter 12.

Priya's loggers table holds tag, room and gateway_tag. Her query `select tag, room from loggers where gateway_tag = 'GW-LOG'` lists all forty loggers with their rooms, and that list became the impact table in NCS's continuity plan.

### 4.3 What not to store

Passwords, private keys and full configuration backups do not belong in a shared asset table. Store a reference ("credential held in vault entry OT-17") and keep the secret in a system designed for it. A spreadsheet of passwords on a shared drive is a common finding in OT assessments.

In Priya's schema, the assets table has an owner column and a source column but no credential column. HMI-C's local administrator password, which she later finds on a sticky note, belongs in the vault with a reference such as OT-17 in the table, not in a cell anyone with the spreadsheet can read.

### 4.4 Data quality fields

Add "source" (documentation, network observation, walk-down) and "last verified" date to each row. An inventory without dates cannot be trusted after a year.

PLC-R2 shows why. Its documented firmware, 2.4, came from the contractor's commissioning records; the passive capture reported 2.1; and Priya's walk-down read 2.1 from the front panel. With a source column, the row now reads firmware 2.1, source walk-down, last verified on the visit date, and a reader can see that the older value came from documents that were never updated after commissioning. Without the date, nobody would know whether the walk-down reading was last week's or two years old.

### Worked example (synthetic NCS)

Priya's schema: assets(tag, type, function, zone, firmware, owner, source, last_verified); loggers(tag, room, gateway_tag); flows(src_tag, dst_tag, protocol, port, approved). Her query "select tag, room from loggers where gateway_tag = 'GW-LOG'" lists all 40 loggers and their rooms, which became the impact list in the facility's continuity plan.

> **Synthetic case — Northgate Cold Storage.** Schema and counts are invented.

### Errors and limits

A model is only as good as its upkeep; assign an owner. Over-normalising a small facility's data can make it harder to use than a well-kept single table.

### Exercises

- **EX010 — Choosing a key.** Why is the painted asset tag a better key than the IP address for PLC-R1? *Rubric:* 3 = stable across re-addressing and replacement; tied to function; 2 = partial; 1 = "easier"; 0 = none.
- **EX011 — Query for an impact list.** Write SQL listing loggers in room "Freezer-2" served by GW-LOG. *Rubric:* 3 = correct where clause on both columns; 2 = one condition; 1 = syntax only; 0 = none.
- **EX012 — Handling a credential field.** A colleague adds a "password" column. What do you replace it with? *Rubric:* 3 = vault reference, secret elsewhere, access-controlled; 2 = remove only; 1 = encrypt the sheet; 0 = keep.

### Synthesis

A small, stable data model with keys, relationships and dates is what turns inventory into answers.

### Continue studying — chapter 04 of 30

[← Chapter 03 (draft)](#ch-03) · [Course chapter index](../SUBJECTS.md) · [Chapter 05 (draft) →](#ch-05)

## Worked answers

<a id="answer-ex010"></a>
**EX010.** The painted tag identifies the function at a fixed location; it survives re-addressing (which changes IP) and hardware replacement (which changes serial number), so history and findings stay attached to the right row.

<a id="answer-ex011"></a>
**EX011.** `select tag from loggers where room = 'Freezer-2' and gateway_tag = 'GW-LOG';`

<a id="answer-ex012"></a>
**EX012.** Replace it with a "credential reference" column holding the vault entry ID (e.g. OT-17); the password itself lives in the access-controlled vault with logging, never in the shared table.